(4号线)08:26时,信号专业报:经后台数据查询,前屿下行00507次(0417车体)车载信号设备故障,不具
备运营条件。OCC组织正线多职能队员打开盖板查看故障信息。
08:36时,经核实,列车运行正常且信号屏无故障信息显示,目前列车运行正常。OCC组织花海公园备车
(0411车体)运行至帝封江上行替开。[二类信息]
(4号线0417车体信号故障跟进)09:12时,00507次(0417车体)在帝封江下行完成单程运营后,运行至
花海公园存车线Ⅰ道停稳。
09:14时,信号专业回复:需登乘处理,故障原因待查。[二类信息]
(4号线0417车体信号故障跟进)11:09时,信号专业回复:故障原因为1端OBCU(车载控制单元)无线单元与
TAU(列车接入单元)无线主机连接中断,重启TAU无线主机后,设备恢复正常,具备上线运营条件。[二类信息]
Disclaimer: The above articles are added by users themselves and are only for typing and communication purposes. They do not represent the views of this website, and this website does not assume any legal responsibility. This statement is hereby made! If there is any infringement of your rights, please contact us promptly to delete it.